Micropore Measurement

Micropore Measurement

Nanoporous materials are found in many research and industrial applications, including controlled drug delivery, energy conversion and storage, etc. A comprehensive characterization of nanoporous materials with regard to pore size, surface area, and pore size distribution is required in order to select and optimize the performance of these materials.

Pore size distribution is a key factor when characterizing porous materials. For example, surface area and porosity are important properties in the field of catalyst design. Total surface area is vital for the performance of solid catalysts since it dictates the number of active sites on the surface of the catalyst. The pore size, pore size distribution, and pore volume control transport phenomena, which in turn dictate selectivity in catalyzed reactions.

Mesopores are pores of internal width between 2 and 50 nm, while micropores are defined as pores with internal diameters of less than 2 nm. Characterization of the micropores involves the use of physisorptive gases that can penetrate into the pores under investigation. Gases used are those which are physically bound at the solid surface, a process referred to as physisorption; for example, N2 at 77K, Ar at 87K, and CO2 at 273K. Micropores are filled at very low relative pressure (P/P0), therefore, specialized instrumentation is required to measure these low pressures.

Due to its excellent adsorption behavior, argon is an ideal probe gas for characterizing the pore structure of absorbent substrates. At 87K, argon fills micropores at a much higher relative pressure versus nitrogen at 77K, thus enabling a more efficient analysis. In order to access the narrowest micropores, the use of CO2 can be utilized. Near room temperature, CO2 molecules can easily reach micropores less than 0.7 nm in size. As such, CO2 has become the standard choice of gas for the characterization of microporous carbons.

On an adsorption isotherm plot, the micropore region is indicated by a large and steep increase of the isotherm near its origin and a subsequent leveling off to a plateau. Extracting the pore size information from the experimental adsorption isotherm requires the use of a realistic pore-filling model. Advances in physical adsorption characterization have led to the development and application of the density functional theory (DFT). Other, simpler macroscopic methods that predate DFT, such as Horvath-Kawazoe (HK) and Dubinin, have been historically used as the pore-filling models.

Through the appropriate materials characterization techniques, the non-local density function theory (NLDFT) pore-size distribution can be calculated, along with pore volume information. The NLDFT pore-filling model correctly describes the adsorption on a molecular level and is applicable over the entire range of micro- and mesopores. NLDFT models for various adsorbent/adsorptive systems are commercially available.

Read More>

Advantages

  • Nitrogen, Argon, or CO2 available for adsorbate gases
  • Micropore and mesopore combination analysis also available, which includes a multi-point BET analysis
  • Several instrument options to ensure best fit for material

Considerations

  • Micropore-only analysis, or combination micropore-mesopore analysis available
  • Appropriate for dry material only

Sample Requirements

Ideally, 2 to 5 grams of test material would be optimum for completing the gas physisorption isotherm micropore measurement. Please note the most commonly used analytical cell is shaped similarly to a test tube, with a 9 mm opening at the top, and a bulb at the bottom. The sample must pass through the tube, which is about 9 mm in diameter, and then it has to sit in the bottom of the bulb (sizes are 2 mL, 4 mL and 7 mL). Larger solid sample pieces can also be accommodated in special analytical cells.

Please contact us to share specific information about your sample and options for suitable sample quantities.

Detection Range

PTL’s gas adsorption micropore analyzers can measure pore size distribution and area measurements in the range of 5 Å to 20 Å (0.5 nm to 2 nm).

Micropore-mesopore combination analysis includes pore measurements in the 5 Å to 3000 Å (0.5 nm to 300 nm) range.

Data Reported

Micropore only analysis: Pore size distribution and area – DFT Pore Volume (cm3/g), DFT Total Pore Area (m2/g).

Micropore-mesopore analysis: Pore size distribution and area – DFT Pore Volume (cm3/g), DFT Total Pore Area (m2/g), BJH Pore Volume (cm3/g), BJH Average Pore diameter (nm), BET Specific Surface Area (m2/g).

Instrumentation

Particle Technology Labs has some of the top players in the industry, such as Micromeritics and Anton Paar/Quantatec.

Micromeritics 3Flex Micropore & 40pt Isotherm

Anton Paar/Quantatec Autosorb iQ-C-XR

Related Articles

Sign-Up for Our Enews

Receive information about particle characterization testing and periodic announcements from Particle Technology Labs.

By submitting this form, you are consenting to receive marketing emails from: Particle Technology Labs, 555 Rogers Street, Downers Grove, IL, 60515, US. You can revoke your consent to receive emails at any time by using the SafeUnsubscribe® link, found at the bottom of every email. Emails are serviced by Constant Contact.